This walking beam reheating furnace is specially supplied for heat copper slab before hot rolling mill. Main technical parameter of the furnace which we supplied to a domestic customer are as following: No. Item Technical Data 1Name of equipment Walking-beam re-heating furnace 2Name of Workpieces Copper slab and copper alloy slab 3Specification of Copper Slab 230mm×(400 650)mm×8000mm 230mm×(400 650)mm×4800mm 210mm×(400 650)mm×7200mm (230mm×620mm×6600mm) 4Production Rate Maximum:60t/h 6pieces/h 5Slab Temperature 800 1050±5 6Temperature of Furnace Chamber Maximum 1150 7Fuel City Gas 8Calorific Volume 3500 3800Kcal/Nm3 9Calculated Calorific Volume 3600Kcal/Nm3 10Pre-heated air temperature 250-400(during normal working time ) 11Thermal efficiency ≥60% 12Thermal Control Method Burner flame is remote, automatic, and continuously controlled. 13Burner Type Flat Flame Burner + Long Flame Burner 14Burner Numbers Total 55 pieces,heating section :35pieces ,soaking section 20 pieces. 15Rated Combustion rate Maximum 6000 Nm3/h 16Chamber Dimension Width 9000× Height 1100(600)× Length 16800mm 17Loading capacity Slab quantity 21pcs/batch×10t/piece=210t/batch 18Total Length of furnace body About 27.6meters 18Feeding & discharging method Side feeding and side discharging 19Loading Method Single Row, centralized in middle position 20Stroke distance of Movable beam Upward move:90mm, Downward move:80mm 21Horizontal moving distance of movable beam 800mm or 400mm×2(it shall be negotiated with buyer) 22Heat Exchanger Model Tube type ( direct cross and counter current ) 23Heating Time About 3.5 hours 24Temperature control Zones 9 zones